dell powervault jbod expansion storages - Latest dell powervault jbod expansion storages Models
Dell Storage MD1400 Direct Attached Storage
- Connectivity
- Unified mode (single path) for daisy chaining of up to 8 enclosures per PERC H830 or PERC H840 (4 enclosures per port, single path)
- Unified mode (recommended redundant path) for daisy chaining up to 4 enclosures per PERC H830 or PERC H840 (4 enclosures connected to both ports via redundant path
- cabling)
- Connectivity per EMM:
- 4 mini-SAS HD connector for connection to the host or expansion
- Service management:
- USB mini b connector (for factory use only)
- Dimensions & Weight
- Height x width x depth:
- MD1400: 8.7 cm (3.43") x 48.2 cm (18.98") x 59.2 cm (23.3") (depth includes PSU handle)
- MD1420: 8.7 cm (3.43") x 48.2 cm (18.98") x 53.9 cm (21.22") (depth includes PSU handle)
- Weight: 28.59 kg (63.03 lb) (maximum configuration)
- 9.0 kg (19.8 lb ) (empty)
- Environmental Operating Conditions
- (A)Temperature
- Operating: 10° to 35°C (50° to 95°F) with maximum temperature gradation of 10°C per hour
- Storage: -40° to 65°C (-40° to 149°F) with temperature gradation of 20°C per hour
- (B)Relative Humidity:
- Operating: 8% to 85% (non-condensing) with maximum humidity gradation of 10% per hour
- Storage: 5% to 95% (non-condensing)
- (C)Altitude
- Operating: -16 to 3048 m (-50 to 10,000 ft)
- Storage: -16 to 10,600 m (-50 to 35,000 ft)
- Expansion Capacity :
- PERC H830/H840 HBA enables expansion to 8 enclosures, PCIe 3.0, 12Gbps SAS, dual-port, 4 ports per enclosure
- Management
- Enclosure Management Modules (EMM)
- 2 EMM provide redundant enclosure management capability
- Power
- Wattage – also supports DC power: AC – 600W; DC – 700W
- Host heat dissipation: AC – 2047 BTU/hr; DC – 2388 BTU/hr
- Input voltage range: 100-240 VAC, auto-sensing; 48 V DC
- Frequency range:50/60 Hz
- Amperage:8.6 A at 100 V, 4.3 A at 240 V
- Supported continuous consumption:
- Up to 1.2 A at +5V
- Up to 0.5 A at +12V
- RAID
- RAID levels 0, 1, 5, 6, 10, 50 and 60
- Rack Support
- Dell ReadyRails™ II static rails for tool-less mounting in 4-post racks with square or unthreaded round holes or tooled mounting in 4-post threaded-hole racks
- Storage
- (A)Drive type
- 3.5" and 2.5" SAS, NL-SAS, SSD, SED (2.5” available with adapter)
- (B)Maximum Raw Capacity (per enclosure)
- Up to 144TB when using 12 x 10TB NL-SAS 3.5" HDDs
Dell Storage MD1280 Dense Enclosure Storage
- Chassis : 5U, 84 hot-pluggable 3.5 drive bays
- Connectivity : 6GB SAS
- Environmental Operating Conditions :
- (A)Temperature
- Operating: 10° t 35°C (50° to 95°F) with maximum temperature gradation of 20°C per hour
- Non-operating: -40° to 65°C (-40° to 149°F) at a maximum altitude of 12,000 m (39,370ft)
- (B)Relative humidity:
- Operating: 10% to 80% (non-condensing) with 29° C (82.4°F) maximum dewpoint.
- Non-operating: 5% to 95% (non-condensing) with 33°C (91°F) maximum dewpoint.
- (C)Altitude
- Operating: -16 to 3048 m (-50 to10,000 ft)
- Storage: -16 to 10,600 m (-50 to 35,000 ft)
- (D)Maximum Usable Capacity :
- Up to 1.3PB when using 2 enclosures, maximum of 168 8TB HDDs
- Management
- Server dependent
- Power
- Wattage: 2800 AC only
- Input voltage range: 200-240 VAC
- Frequency range: 50/60 Hz
- RAID Controllers
- 2 Enclosure Management Modules (EMM) provide redundant enclosure management capability
- Scalability
- Up to 672TB when using 84 x 8TB NL-SAS 3.5" HDDs
- Storage
- Drive performance and capacity:
- 3.5 NL-SAS 6Gb HDD (7.2K): 4TB, 6TB
- 3.5 NL-SAS 4kn 6Gb HDD (7.2k): 6TB
- 3.5 NL-SAS 512e 6Gb HDD (7.2K): 8TB
Dell PowerVault MD1220 Storage
- Operating System: Refer to the PERC RAID Card details for supported Operating Systems PERC H810
- Back-Panel Connectors :
- (A)SAS connectors (per EMM):
- 1 SAS (SFF 8088) "IN" connector for connection to the host
- 1 SAS (SFF 8088) "OUT" connector for expansion to an additional enclosure
- (B) Serial connector (per EMM):
- 1 6-pin UART mini-DIN connector (for factory use only)
- Chassis
- Height: 8.7cm (3.43 inches)
- Width: 48.2cm (18.98 inches)
- Depth: 54.1 (21.30 inches)
- Weight: 23.31 kg (51 lb) (maximum configuration)
- 8.61 kg (19 lb) (empty)
- Connectivity :
- Support for the following configurations:
- (A)Unified mode (single path) for daisy chaining of up to 8 enclosures per PERC H810 (4 enclosures per port, single path)
- (B)Unified mode (redundant path) for daisy chaining up to 4 enclosures per PERC H810 (4 enclosures connected to both ports via redundant path cabling)
- (C)Split mode with dual Enclosure Management Modules providing direct connectivity to drives 0 through 11 and a separate connectivity to drives 12 through 23
- Environmental Operating Conditions :
- (A)Temperature
- Operating: 10° to 35°C (50° to 95°F) with maximum temp gradation of 10°C per hour
- Storage: -40° to 65°C (-40° to 149°F) with temp gradation of 20°C per hour
- Supports Fresh Air cooling, up to 35 degrees Celsius
- (B)Relative humidity
- Operating: 8% to 85% (non-condensing) with maximum humidity gradation of 10% per hour
- Storage: 5% to 95% (non-condensing)
- (C)Altitude
- Operating: -16 to 3048 m (-50 to 10,000 ft)
- Storage: -16 to 10,600 m (-50 to 35,000 ft)
- LED Indicators :
- (A)Front panel
- 1 two-color LED indicator for system status
- 2 single-color LED indicators for power and split mode
- (B)Hard-drive carrier
- 1 single-color activity LED
- 1 two-color LED status indicator per drive
- (C)EMM
- 3 two-color LED status indicators: one for each of the EMM SAS ports and one for the EMM status
- 1 single-color Unit Identification LED for each EMM
- (D)Power supply/cooling fan module
- 3 LED status indicators for Power supply/cooling fan fault, AC power, and DC power
- Management : Enclosure Management Modules (EMM): 2 EMM modules provide redundant enclosure management capability
- Power : Two fully redundant power supplies; supports DC power
- (A)Wattage: AC - 600 W; DC - 700 W
- (B)Heat dissipation: AC - 2047 BTU/hr; DC - 2388 BTU/hr
- (C)Voltage: 100-240VAC; 48V DC
- (D)Frequency: 50/60Hz
- (E)Amperage: 8.6 A at 100 V, 4.3 A at 240 V
- (F)Available Hard Drive Power (per slot)
- Supported drive power consumption (continuous):
- up to 1.2 A at +5V
- up to 0.5 A +12V
- RAID : PERC H800 supports RAID levels 0, 1, 5, 6, 10, 50 and 60.
- See PERC H800 server compatability matrix for a list of currently supported servers
- Storage :
- (A)Drives:
- Up to twenty-four (24) 2.5-inch hot-pluggable SAS Hard Disk Drives (HDDs) at 7.2K, 10K, 15K rpm and SAS Solid State Drives (SSDs).
- (B)Drive performances and capacities
- (I)2.5” 6Gbps SAS:
- HDD 15K – 146GB, 300GB, 600GB
- HDD 10K – 300GB, 600GB, 900GB, 1.2GB
- HDD 10K 512e – 1.8TB
- HDD 7.2K – 500GB, 1TB
- SSD – 200GB, 800GB value SLC
- SSD – 400GB mainstream SLC
- SSD – 800GB RI MLC
- SSD – 200GB, 400GB WI SLC
- SSD – 2TB eMLC
- (II)2.5” 12Gbps SAS
- HDD 15K – 600GB
- HDD 7.2K NL-SAS 512e – 2TB
- SSD – 200GB, 400GB, 800GB 1.6TB MU MLC
- SSD – 200GB, 400GB, 800GB WI MLC
- SSD – 800GB, 1.6TB RI MLC
- (C)Maximum Capacity (per enclosure)
- Up to 48TB when using 24 x 2TB NL-SAS 2.5" HDDs
- (D)Expansion Capabilities
- PERC H810 enables expansion to 8 enclosures, 4 per port
Dell PowerVault MD1200 Storage
- Operating System: Refer to RAID Card for details on supported Operating Systems PERC H810
- SAS connectors (per EMM): 1 SAS (SFF 8088) IN connector for connection to the host, 1 SAS (SFF 8088) OUT connector for expansion to an additional enclosure
- Serial connector (per EMM): 1 6 pin UART mini-DIN connector (for factory use only)
- Chassis Height : 8.7cm (3.43 inches)
- Chassis Width : 48.2cm (18.98 inches)
- Chassis Depth : 59.4 (23.39 inches)
- Chassis Weight : 28.39 kg (62.6 lb) (maximum configuration)8.84 kg (19.5 lb) (empty)
- SAS connectors (per EMM): 1 SAS (SFF 8088) IN connector for connection to the host, 1 SAS (SFF 8088) OUT connector for expansion to an additional enclosure
- Serial connector (per EMM):1 6-pin UART mini-DIN connector (for factory use only)
- Connectivity:
- (A)Unified mode (single path) for daisy chaining of up to 8 enclosures per PERC H810 (4 enclosures per port, single path)
- (B)Unified mode (redundant path) for daisy chaining up to 4 enclosures per PERC H810 (4 enclosures connected to both ports via redundant path cabling)
- (C)Split mode with dual Enclosure Management Modules providing direct connectivity to drives 0 through 5 and a separate connectivity to drives 6 through 11.
- Environmental Operating Conditions:
- (A)Temperature:
- Operating: 10° to 35°C (50° to 95°F) with maximum temp gradation of 10°C per hour
- Storage: -40° to 65°C (-40° to 149°F) with temp gradation of 20°C per hour
- Supports Fresh Air cooling, up to 35 degrees Celsius
- (B)Relative humidity:
- Operating: 8% to 85% (non-condensing) with maximum humidity gradation of 10% per hour
- Storage: 5% to 95% (non-condensing)
- (C)Altitude:
- Operating: -16 to 3048 m (-50 to 10,000 ft)
- Storage: -16 to 10,600 m (-50 to 35,000 ft)
- LED Indicators :
- (A)Front panel
- 1 two-color LED indicator for system status
- 2 single-color LED indicators for power and split mode
- (B)Drive carrier
- 1 single-color activity LED
- 1 two-color LED status indicator per drive
- (C)EMM
- 3 two-color LED status indicators: one each for the two EMM SAS ports and one for the EMM status
- 1 single-color Unit Identification LED for each EMM
- (D)Power supply/cooling fan module
- 3 LED status indicators for power supply status, power supply/fan fault and AC status
- Management :
- 2 Enclosure Management Modules(EMM) provide redundant enclosure management capability
- Power :
- Two fully redundant power supplies; supports DC power
- Wattage: AC - 600 W; DC – 700 W
- Heat dissipation: AC - 2047BTU/hr; DC - 2388 BTU/hr
- Voltage: 100-240 VAC, auto sensing; 48V DC
- Frequency: 50/60 Hz
- Amperage: 8.6 A at 100 V, 4.3 A at 240 V
- Available Drive Power (per slot)
- Supported drive power consumption (continuous):
- up to 1.16 A at +5V
- up to 1.6 A +12V
- RAID : PERC H800 supports RAID levels 0, 1, 5, 6, 10, 50 and 60.
- Storage :
- (A)Drives :
- Up to twelve (12) hot-pluggable SAS Hard Disk Drives (HDDs) at 7.2K, 10K and 15K rpm and SAS Solid State Drives (SSDs)
- (B)Drive performances and capacities :
- (I)3.5” 6Gbps SAS:
- HDD 15K – 300GB, 450GB, 600GB
- HDD 7.2K – 1TB, 2TB, 3TB, 4TB
- HDD 7.2K NL-SAS 512e – 6TB
- (II)3.5” 12Gbps SAS:
- HDD 7.2K NL-SAS 512e – 6TB, 8TB, 10TB
- (III)2.5” 6Gbps SAS with 3.5” carrier:
- HDD 10K – 300GB, 600GB, 900GB, 1.2TB
- HDD 10K 512e– 1.8TB
- SSD – 400GB mainstream SLC
- SSD – 200GB, 800GB value SLC
- SSD – 800GB RI MLC
- SSD – 200GB, 400GB WI SLC
- (IV)2.5 12Gbps SAS with 3.5 carrier: 7.2K HDD NL-SAS 512e 2TB, SSD 200GB, 400GB, 800GB, 1.6TB MU MLC
- SSD – 200GB, 400GB, 800GB WI MLC
- SSD – 800GB, 1.6TB RI MLC
- (C)Maximum Capacity (per enclosure): Up to 120TB when using 12 x 10TB NL-SAS 3.5 HDDs
- (D)Expansion Capabilities: PERC H810 Host RAID adapter enables expansion to 8 enclosures (4 enclosures per port)